Case studies

Real sites, real data, labelled honestly.

How AmpVerve works with fleet depots, utilities and standards bodies. Every result on this page says whether it was measured, modelled or demonstrated, and shows its method, so you can check it before you trust it.

  • Measured
    A real site, real metered data, compared against a baseline agreed in advance.
  • Modelled
    A worked example from stated assumptions and published prices. Not a customer result.
  • Demonstrated
    Proven in a controlled test with named partners. Testing, not certification.
Pilot in progressFleets, public sectorLondon

A London borough council fleet depot, shadow piloted before a single charger is touched

  • About 30electric fleet vehicles in the pilot
  • 4,427charging sessions analysed
  • 90 daysof shadow running
  • 0chargers controlled during the shadow phase

The challenge

Every vehicle must leave the depot charged for its round. The council wanted to know what smarter charging and grid flexibility would be worth before changing anything on site.

What we are doing

We bring vehicle telematics, half-hourly site metering and charger session data into one view. Each day AmpVerve calculates the plan it would have run, against what actually happened, without controlling a charger.

Status

The shadow pilot is running. We will publish measured results when it completes and the council agrees. Until then we quote no savings from this site.

Shadow first means the depot sees the plan, and the evidence behind it, before it hands over a single charger.

ModelledFleets, worked exampleGreat Britain

A 20-van depot: half the peak, room to grow, and a lower bill

148 to 71 kW

Peak charging demand when every van plugs in on arrival, against a schedule that fills every van by its departure time. Freed connection capacity is the room to add vehicles before a grid upgrade.

  • 20electric vans, 7.4 kW chargers
  • 500 kWhdrawn from the grid each working day
  • About 10more vans on the same connection
  • £10k to £19ka year lower energy cost

The challenge

Vans return around 17:30 and plug in together, so charging lands on the evening peak, at the highest prices, and uses most of the depot’s connection. Adding vehicles looks like it needs a bigger supply.

What AmpVerve does

Plans each charge back from each van’s 07:00 departure, inside the connection limit, and moves the energy into the cheapest overnight hours. Readiness is a hard limit: a van that needs charge gets it.

The modelled result

Peak charging demand roughly halves, freeing about 75 kW. Keeping half of that as a safety margin leaves room for about 10 more vans charged in the same window. The price gap between evening and overnight energy is worth £10,000 to £19,000 a year.

Assumptions behind this example
  • 20 vans, each needing 25 kWh a day from the grid (about 75 miles at 3.3 miles per kWh, with charging losses), 250 working days a year.
  • Unmanaged: all vans start charging at 7.4 kW on arrival at 17:30, so 148 kW for about 3.4 hours.
  • Scheduled: the same 500 kWh delivered between 00:00 and 07:00, about 71 kW.
  • Saving range uses an illustrative non-domestic time-of-use price gap of 8p to 15p per kWh between evening and overnight energy (central 12p, about £15,000 a year). Excludes standing charges, capacity charges and VAT.
  • Flexibility income is not included. It depends on the routes open to your site, and we calculate it for your depot rather than quote a typical figure.
  • Your result depends on your tariff, connection, building load and duty cycles. The free headroom review replaces every assumption here with your own data.
DemonstratedUtilities, vehicle-to-gridUnited States, October 2026

Utility controls relayed to chargers over an open standard, at the V2G Forum testbed

1,110 of 1,110

meter readings reported back by AmpVerve were accepted by the utility server, after 39 controls were received and relayed over IEEE 2030.5.

  • 39utility controls received and relayed
  • 171 of 171responses accepted
  • 23 of 25power steps within 0.5%
  • 27 to 29 OctDetroit demonstration

The challenge

Utilities want to send grid controls to chargers from any manufacturer and know each control arrived, was acted on and was reported back. Most vehicle-to-grid projects prove this with one vendor’s equipment end to end.

What we did

AmpVerve took the aggregator role in the AC demonstration of the V2G Forum interoperability testbed, with PNNL, Emporia and Pacific Power. We took IEEE 2030.5 controls from the utility server, passed them to the charging equipment and reported status and metering back.

The result

Each control was tracked through every stage on its own: received, acknowledged, executed and reported. Interoperability testing, not certification. Vehicle-to-grid is not live for AmpVerve customers today.

A gateway acknowledging a control is not the same as a charger doing it. We record every stage separately, so the evidence holds up.

ModelledUtilities, dynamic network tariffSwitzerland and the Netherlands, September 2026

A bidirectional charging schedule against a 15-minute network tariff, for IEA Task 53

96 of 96

quarter-hour network prices turned into one explainable charge and discharge schedule, with every setpoint traceable to a price.

  • 12setpoints across 8 power levels
  • 45 to 80%battery kept in its agreed band
  • 40.5 kWhin over the day
  • 16.6 kWhout over the day

The challenge

Primeo Energie’s dynamic network tariff changes price every 15 minutes. IEA Task 53 asked how a bidirectional vehicle could follow it and still leave with the charge its driver needs.

What we did

A constrained optimisation that turns the day’s 96 prices into a schedule, allowing for charge taper, exported as operator setpoints, a full 96-interval file and a JSON audit record.

The result

The schedule charged in the cheapest intervals and discharged into the dearest. We presented it at the third Task 53 workshop, hosted by ElaadNL in Arnhem on 7 September 2026.

Assumptions behind this example
  • Primeo Energie network tariff published for 28 August 2026, 96 quarter-hour intervals.
  • A representative 60 kWh vehicle battery and an 11 kW each-way charger.
  • A worked example for a research workshop, not a customer result.

Make your depot the next case study.

Your first assessment and your 90-day pilot are free, on the chargers you already have. We show how many more vehicles your connection can charge and what smarter timing is worth, before we touch anything. After the pilot, AmpVerve is paid only from a share of the savings and grid income it creates. If we deliver nothing, you pay nothing.

Modelled figures are estimates with their method stated. Measured figures are compared against a baseline agreed with the site. Nothing on this page is a guarantee of savings or income.